bannière
Maison

Chambre d'essai à haute et basse température

Chambre d'essai à haute et basse température

  • Key Differences in Using Environmental Test Chambers Between Summer and Winter
    Nov 26, 2025
    The core difference lies in the impact of ambient temperature and humidity variations on equipment operating efficiency, energy consumption, and test accuracy. Targeted measures for temperature/humidity control, heat dissipation/anti-freezing, and maintenance are required. Specific differences and precautions are as follows: I. Core Difference Comparison Table Dimension Summer Operation Characteristics Winter Operation Characteristics Ambient Conditions High temperature & high humidity (room temp: 30-40℃, RH: 60%-90%) Low temperature & low humidity (room temp: 0-15℃, RH: 30%-60%) Equipment Load High refrigeration system load, prone to overload High heating system load; humidification compensation required for certain models (e.g., temperature-humidity chambers) Impact on Test Accuracy High humidity causes condensation, affecting sensor accuracy Low temperature leads to pipeline freezing; low humidity may reduce stability of humidity tests Energy Consumption High refrigeration energy consumption High heating/humidification energy consumption   II. Season-Specific Precautions (1) Summer Operation: Focus on High Temperature/High Humidity/Overload Prevention 1. Ambient Heat Dissipation Management Reserve ≥50cm ventilation space around the chamber; avoid direct sunlight or proximity to heat sources (e.g., workshop ovens, air conditioner outlets). Ensure laboratory air conditioning operates normally, maintaining room temperature at 25-30℃. If room temp exceeds 35℃, install industrial fans or cooling devices to assist heat dissipation and prevent refrigeration system overload protection triggered by high ambient temperatures. 2. Moisture & Condensation Control Regularly clean chamber door gaskets with a dry cloth to prevent sealant aging and air leakage caused by high humidity. After humidity tests, open the chamber door promptly for ventilation and wipe off condensation to avoid moisture damage to sensors (e.g., humidity sensors). 3. Equipment Operation Protection Avoid prolonged continuous operation of extreme low-temperature tests (e.g., below -40℃). Recommend shutting down for 1 hour after 8 hours of operation to protect the compressor. Periodically inspect refrigeration system radiators (condensers) and remove dust/debris (blow with compressed air monthly) to ensure heat dissipation efficiency. (2) Winter Operation: Focus on Anti-Freezing/Low Humidity/Startup Failure Prevention 1. Ambient Temperature Guarantee Maintain laboratory temperature above 5℃ (strictly follow 10℃ if specified as the minimum operating temperature) to prevent pipeline freezing (e.g., refrigeration capillaries, humidification pipes). For unheated laboratories, install an insulation cover (with ventilation holes reserved) or activate the "preheating mode" (if supported) before testing. 2. Humidification System Maintenance Use distilled water in the humidification tank to avoid pipe blockage from impurity crystallization at low temperatures. Drain water from the humidification tank and pipelines during long-term non-use to prevent freezing-induced component damage. 3. Startup & Operation Specifications In low-temperature environments, activate "standby mode" for 30 minutes preheating before setting test parameters to avoid compressor burnout from excessive startup load. If startup fails (e.g., compressor inactivity), check power voltage (prone to instability during winter peak hours) or contact after-sales to inspect pipeline freezing. 4. Low Humidity Compensation For low-humidity tests (e.g., ≤30% RH), winter dryness may cause rapid humidity. Adjust humidification frequency appropriately and use the "humidity calibration" function to reduce fluctuations. III. General Precautions (All Seasons) Calibrate temperature/humidity sensors quarterly to ensure data accuracy. Clean air filters monthly to maintain airflow circulation. Arrange test samples evenly to avoid blocking internal air ducts and ensure temperature/humidity uniformity. For long-term non-use: Run the chamber for 1 hour monthly in summer (moisture prevention) and drain pipeline water in winter (freezing prevention). By addressing seasonal environmental variations, equipment service life can be extended, and test failures caused by temperature/humidity fluctuations avoided—aligning with the high precision and stability requirements of the industrial test equipment industry.    
    EN SAVOIR PLUS
  • Differences Between High-Low Temperature Test Chamber and Thermal Shock Chamber
    Nov 26, 2025
    In industrial product reliability testing, high and low temperature test chambers and temperature shock test chambers are core environmental testing equipment, both simulating extreme temperatures to verify product durability. However, they differ fundamentally: the former focuses on gradual temperature-humidity cycles, while the latter on instantaneous thermal shock. Clarifying these differences is key to matching test needs and ensuring data validity. 1. Rate High-Low Temperature Test Chamber: Slow, with a regular rate of 0.7∼1 ℃/min, and rapid versions can reach 5∼15 ℃/min. Thermal Shock Chamber: Abrupt, with instant switching. 2. Structure High-Low Temperature Test Chamber: Single-chamber structure, integrating heating, refrigeration, and humidification functions. Thermal Shock Chamber: Multi-chamber structure, including high-temperature chamber, low-temperature chamber, and test chamber. 3. Temperature Continuity High-Low Temperature Test Chamber: The temperature changes smoothly without any "shock sensation". Thermal Shock Chamber: The temperature changes by leaps and bounds, with a common temperature range of −40∼150℃. 4. Application High-Low Temperature Test Chamber: Suitable for temperature endurance testing of general products such as electronic devices, household appliances, and building materials. Thermal Shock Chamber: Suitable for shock resistance testing of temperature-sensitive products such as automotive electronics, semiconductors, and aerospace components. 5. Core Position & Test Purpose High-Low Temperature Test Chamber: Simulates gradual temperature (and humidity) changes to test product stability under slow thermal variation (e.g., electronic devices’ performance after gradual cooling to -40℃ or heating to 85℃). Thermal Shock Chamber: Simulates abrupt temperature switching (≤30s transition) to test product resistance to extreme thermal shock (e.g., auto parts adapting to drastic day-night temperature changes, aerospace components’ tolerance to sudden high-low temperature shifts). Summary The high and low temperature test chamber is a "slow-paced endurance test", while the temperature shock chamber is a "fast-paced explosive power challenge". Just based on whether the product will encounter "sudden cold and heat" in the actual usage scenario, the precise selection can be made.
    EN SAVOIR PLUS
  • What should we pay attention to when using a thermal shock test chamber (water-cooled)?
    Nov 22, 2025
    I. Before Operation Use deionized water or distilled water as cooling water (to prevent scale formation); control temperature at 15-30℃, pressure at 0.15-0.3MPa, flow rate ≥5L/min. Clean the Y-type filter element in advance to ensure unobstructed water flow. Inspect water supply/drainage pipelines for secure connections, no leakage or kinking; keep drainage ports unobstructed with a height difference ≥10cm. Ensure the environment is ventilated and dry, grounding resistance ≤4Ω, and power supply (AC380V±10%) stable. Keep the inner chamber and shelves clean. Sample volume ≤1/3 of effective capacity, with weight evenly distributed on shelves. Seal moisture-sensitive parts of non-hermetic samples to avoid condensation affecting test accuracy. II. During Operation Real-time monitor cooling water pressure, flow rate and temperature. Immediately shut down for troubleshooting (pipeline blockage, leakage or chiller failure) if pressure drops sharply, flow is insufficient or temperature exceeds 35℃. Set high/low temperature parameters per GB/T, IEC and other standards (not exceeding rated range); control heating/cooling rate ≤5℃/min. Prohibit instantaneous switching between extreme temperatures. Do not open the door arbitrarily during operation (to prevent scalding/frostbite from hot/cold air). Use protective gloves for emergency sample handling. Shut down immediately for maintenance upon alarm (overtemperature, water shortage, etc.); prohibit forced operation. III. After Test Turn off power and cooling water inlet/outlet valves; drain residual water in pipelines. Clean the water tank and replace water monthly; add special water stabilizer to extend pipeline service life. Wipe the inner chamber and shelves after temperature returns to room temperature. Clean the air filter (1-2 times monthly); inspect pipeline seals and replace aging/leaking ones promptly. For long-term non-use: Power on and run for 30 minutes monthly (including water cooling system circulation), inject anti-rust protection fluid into pipelines, and cover the equipment with a dust cover in a dry, ventilated place. IV. Prohibitions Prohibit using unqualified water (tap water, well water, etc.) or blocking filters/drainage ports (to avoid affecting heat dissipation). Prohibit overloading samples or unauthorized disassembly/modification of water cooling pipelines/core components. Repairs must be performed by professionals. Prohibit frequent start-stop (wait ≥5 minutes after shutdown before restarting). Prohibit placing flammable, explosive or corrosive substances.
    EN SAVOIR PLUS
  • Differences between High and Low Temperature Test Chamber and Constant Temperature Test Chamber
    Nov 13, 2025
        In environmental reliability testing, high-low temperature humidity test chambers and constant temperature and humidity test chambers are easily confused due to similar names, but they differ significantly in testing capabilities, applications and technical characteristics. Accurate distinction and selection are key to ensuring valid test data. This blog will analyze the core differences and provide selection suggestions. I. Core Definition: Essential Distinction of Functional Boundaries     The core difference between the two starts with functional positioning, which directly determines the applicable scenarios.     The core of the constant temperature and humidity test chamber is "maintaining stability". It can accurately control and maintain the set temperature and humidity for a long time, and is used to simulate the long-term performance of products in specific environments, such as electronic component stability testing and textile temperature-humidity sensitivity testing. Its core requirement is "steady-state environmental performance verification".     The high-low temperature humidity test chamber focuses on "dynamic simulation". In addition to precise temperature and humidity control, it has a wide-range fluctuation capability, which can simulate environments such as high-low temperature cycles and alternating humidity and heat, such as extreme temperature differences during product transportation and diurnal temperature-humidity changes of outdoor equipment. Its core requirement is "dynamic environmental reliability verification". II. Key Differences: Multi-dimensional Analysis from Technology to Application 1. Temperature and Humidity Range and Fluctuation Capacity     The constant temperature and humidity chamber has a mild temperature and humidity range (temperature 0℃-100℃, humidity 30%-95%RH) and high control precision (temperature fluctuation ±0.5℃, humidity ±2%RH), but no extreme temperature-humidity impact capability.     The high-low temperature humidity chamber has a wider temperature and humidity coverage (temperature -70℃~200℃, humidity 10%-98%RH) and rapid change capability (heating rate 3℃/min-15℃/min, cooling rate 1℃/min-10℃/min), which can realize rapid cycle switching between "high temperature and high humidity - low temperature and low humidity"—a feature unavailable in the former. 2. Differences in Core Technical Architecture     The constant temperature and humidity chamber adopts single-stage compression refrigeration, conventional resistance heating, and steam or ultrasonic humidification. Its system design focuses on "energy saving and stability", with simple structure and low operating cost.     To meet extreme needs, the high-low temperature humidity chamber uses cascade refrigeration, rapid-heating tubes, and its humidity system includes a fast-response dehumidification module, with a thicker insulation layer on the chamber wall. Its technical complexity and manufacturing cost are much higher than the former. 3. Applicable Scenarios and Testing Purposes     The constant temperature and humidity chamber is used for steady-state environmental adaptability testing, such as electronic component aging and pharmaceutical storage simulation, to verify the performance consistency and durability of products in a fixed environment.     The high-low temperature humidity chamber focuses on dynamic reliability testing, such as high-low temperature cycling of auto parts and extreme environment simulation of aerospace products, to expose product defects (material aging, structural deformation, etc.) under drastic environmental changes.     In summary, the constant temperature and humidity chamber guards the steady-state environment, while the high-low temperature humidity chamber challenges the dynamic environment. There is no absolute advantage or disadvantage between the two. Only by matching needs, clarifying scenarios and budgets can the test truly guarantee product quality.
    EN SAVOIR PLUS
  • Lab Two-Chamber Thermal Shock Chamber
    Nov 03, 2025
    The two-chamber thermal shock chamber is a highly reliable environmental testing device specifically designed for evaluating the ability of products to withstand extreme temperature changes. It simulates harsh temperature shock conditions to rapidly expose the possible failures of materials, electronic components, automotive parts and aerospace equipment during rapid thermal expansion and contraction, such as cracking, performance degradation and connection faults. It is a key tool for improving product quality and reliability. The core design concept of this device lies in efficiency and harshness. It has two independently controlled test chambers inside: a high-temperature chamber and a low-temperature chamber, which are respectively maintained at the set extreme temperatures continuously. The sample to be tested is placed in an automatic mechanical basket. During the test, the basket will be rapidly switched between the high-temperature zone and the low-temperature zone under the program control, instantly exposing the sample to a huge temperature difference environment, thus achieving the true "thermal shock" effect. Compared with another mainstream three-chamber (static) impact chamber, the significant advantage of the two-chamber type lies in its extremely fast temperature conversion speed and short temperature recovery time, ensuring the strictness and consistency of the test conditions. It is highly suitable for testing samples with sturdy structures that can withstand mechanical movement, and the testing efficiency is extremely high. Its working principle determines that during the testing process, the temperature fluctuation of the high and low temperature chamber is small, it can quickly return to the set point, and is not significantly affected by the sample load. This equipment is widely used in fields such as semiconductors, integrated circuits, national defense science and technology, automotive electronics, and new material research and development, for conducting reliability tests as required by various international standards. Its main technical parameters include a wide temperature range (high temperatures up to +150°C to +200°C, low temperatures down to -40°C to -65°C or even lower), precise temperature control accuracy, and customizable sample area sizes. The Lab two-chamber thermal shock chamber, with its irreplaceable rapid temperature change capability, has become the ultimate touchstone for testing the adaptability and durability of products in extreme temperature environments, providing a strong guarantee for the precision manufacturing and reliability verification of modern industry.
    EN SAVOIR PLUS
  • Dragon Heat Flow Meter Temperature Control Test
    Oct 29, 2025
    Temperature control tests are usually conducted under two conditions: no-load (without sample placement) and load (with standard samples or actual samples being tested placed). The basic testing steps are as follows:   1. Preparatory work: Ensure that the heat flow meter has been fully preheated and is in a stable state. Prepare high-precision temperature sensors that have undergone metrological calibration (such as multiple platinum resistance PT100), and their accuracy should be much higher than the claimed indicators of the heat flow meter to be measured. 2. Temperature uniformity test: Multiple calibrated temperature sensors are arranged at different positions within the working area of the heat flow meter's heating plate (such as the center, four corners, edges, etc.). Set one or more typical test temperature points (such as -20°C, 25°C, 80°C). After the system reaches thermal stability, simultaneously record the temperature values of all sensors. Calculate the maximum, minimum and standard deviation of these readings to evaluate the uniformity. 3. Temperature control stability and accuracy test: Fix a calibrated temperature sensor at the center of the heating plate (or closely attach it to the built-in sensor of the instrument). Set the target temperature and start the temperature control. Record the entire process from the start to reaching the target temperature (for analyzing response speed and overshoot). After reaching the target temperature, continuously record for at least 1-2 hours (or as per standard requirements), with a sampling frequency high enough (such as once per second), and analyze the recorded data. 4. Load test: Place standard reference materials with known thermal physical properties or typical samples to be tested between the hot plates. Repeat step 3 and observe the changes in temperature control performance under load conditions. Load will directly affect the thermal inertia of the system, thereby influencing the response speed and stability.   When you are choosing or using a heat flow meter, be sure to carefully review the specific parameters regarding temperature control performance in its technical specification sheet and understand under what conditions (no-load/load) these parameters were measured. Lab will provide clear and verifiable temperature control test data and reports.
    EN SAVOIR PLUS
  • How is over-temperature protection carried out in a temperature test chamber?
    Oct 23, 2025
    The over-temperature protection of the temperature test chamber is a multi-level and multi-redundant safety system. Its core purpose is to prevent the temperature inside the chamber from rising out of control due to equipment failure, thereby protecting the safety of the test samples, the test chamber itself and the laboratory environment.   The protection system usually consists of the following key parts working together: 1. Sensor: The main sensor is used for the normal temperature control of the test chamber and provides feedback signals to the main controller. An independent over-temperature protection sensor is the key to a safety system. It is a temperature-sensing element independent of the main control temperature system (usually a platinum resistance or thermocouple), which is placed by strategically at the position within the box that best represents the risk of overheating (such as near the heater outlet or on the top of the working chamber). Its sole task is to monitor over-temperature. 2. Processing unit: The main controller receives signals from the main sensor and executes the set temperature program. The independent over-temperature protector, as an independent hardware device, is specifically designed to receive and process the signals from the over-temperature protection sensor. It does not rely on the main controller. Even if the main controller crashes or experiences a serious malfunction, it can still operate normally. 3. Actuator: The main controller controls the on and off of the heater and the cooler. The safety relay/solid-state relay receives the signal sent by the over-temperature protector and directly cuts off the power supply circuit of the heater. This is the final execution action.   The over-temperature protection of the temperature test chamber is a multi-level, hard-wire connected safety system designed based on the concepts of "redundancy" and "independence". It does not rely on the main control system. Through independent sensors and controllers, when a dangerous temperature is detected, it directly and forcibly cuts off the heating energy and notifies the user through sound and light alarms, thus forming a complete and reliable safety closed loop.
    EN SAVOIR PLUS
  • The Applicability of Temperature Test Chambers to the Testing of Household Environmental Products
    Oct 18, 2025
    A variety of products used in home environments (more common test objects) such as televisions, air conditioners, refrigerators, washing machines, smart speakers, routers, etc., as well as environmental protection products used to improve the home environment: such as air purifiers, fresh air systems, water purifiers, humidifiers/dehumidifiers, etc. No matter which category it is, as long as it needs to work stably for a long time in a home environment, it must undergo strict environmental reliability tests. The high and low temperature test chamber is precisely the core equipment for accomplishing this task.   The home environment is not always warm and pleasant, and products will face various harsh challenges in actual use. This mainly includes regional climate differences, ranging from the severe cold in Northeast China (below -30°C) to the scorching heat in Hainan (up to over 60°C in the car or on the balcony). High-temperature scenarios such as kitchens close to stoves, balconies exposed to direct sunlight, and stuffy attics, etc. Or low-temperature scenarios: warehouses/balconies without heating in northern winters, or near the freezer of refrigerators. The high and low temperature test chamber, by simulating these conditions, "accelerates" the aging of products in the laboratory and exposes problems in advance.   The actual test cases mainly cover the following aspects: 1. The smart TV was continuously operated at a high temperature of 55°C for 8 hours to test its heat dissipation design and prevent screen flickering and system freezing caused by overheating of the mainboard. 2. For products with lithium batteries (such as cordless vacuum cleaners and power tools), conduct charge and discharge cycles at -10°C to assess the battery performance and safety at low temperatures and prevent over-discharge or fire risks. 3. The air purifier (with both types of "environmental product" attributes) undergoes dozens of temperature cycles between -20°C and 45°C to ensure that its plastic air ducts, motor fixing frames and other structures will not crack or produce abnormal noises due to repeated thermal expansion and contraction. 4. Smart door lock: High-temperature and high-humidity test (such as 40°C, 93%RH) to prevent internal circuits from getting damp and short-circuited, which could lead to fingerprint recognition failure or the motor being unable to drive the lock tongue.   High and low temperature test chambers are not only applicable but also indispensable for the testing of household environmental products. By precisely controlling temperature conditions, it can ensure user safety and prevent the risk of fire or electric shock caused by overheating or short circuits. Ensure that the product can work stably in different climates and home environments to reduce after-sales malfunctions. And it can predict the service life of the product through accelerated testing. Therefore, both traditional home appliance giants and emerging smart home companies will take high and low temperature testing as a standard step in their product development and quality control processes.
    EN SAVOIR PLUS
  • Le principe d'équilibrage de la température à l'intérieur de la chambre d'essai par la vanne d'air
    Sep 22, 2025
    Son principe de base repose sur un système de rétroaction négative en boucle fermée (chauffage, mesure, contrôle). En termes simples, il s'agit de contrôler précisément la puissance des éléments chauffants à l'intérieur du boîtier afin de compenser la dissipation thermique due à l'environnement extérieur, maintenant ainsi une température d'essai constante, supérieure à la température ambiante. Le processus de stabilisation de la température par la vanne d'air est un circuit fermé dynamique à ajustement continu : Tout d'abord, définissez une température cible. Le capteur de température mesure la température réelle à l'intérieur du boîtier en temps réel et transmet le signal au régulateur PID.Lorsque le régulateur PID calcule la valeur d'erreur, il calcule la puissance de chauffage à ajuster en fonction de cette valeur grâce à l'algorithme PID. Cet algorithme prend en compte trois facteurs.P (proportion) : Quelle est l'ampleur de l'erreur de courant ? Plus l'erreur est importante, plus la plage de réglage de la puissance de chauffage est grande.Intégrale : Accumulation d'erreurs sur une certaine période. Elle sert à éliminer les erreurs statiques (par exemple, s'il y a toujours un léger écart, le terme d'intégration augmentera progressivement sa puissance jusqu'à l'éliminer complètement).D (différentiel) : Taux de variation de l'erreur de courant. Si la température approche rapidement de la cible, la puissance de chauffage sera réduite à l'avance pour éviter tout dépassement.3. Le contrôleur PID envoie le signal calculé au contrôleur de puissance de l'élément chauffant (tel qu'un relais statique SSR), régulant avec précision la tension ou le courant appliqué au fil chauffant, contrôlant ainsi sa génération de chaleur.4. Le ventilateur de circulation fonctionne en continu pour assurer une distribution rapide et uniforme de la chaleur générée par le chauffage. Il transmet également rapidement les variations du signal du capteur de température au contrôleur, ce qui optimise la réactivité du système. L'équilibreur à soupape d'air mesure le volume d'air, dont la densité varie avec la température. Pour une même valeur de pression différentielle, le débit massique ou volumique correspondant à des densités d'air différentes est différent. Par conséquent, la température doit être stabilisée à une valeur fixe connue afin que le microprocesseur de l'instrument puisse calculer avec précision le volume d'air dans des conditions standard, en fonction de la pression différentielle mesurée, à l'aide de la formule prédéfinie. Une température instable compromet la fiabilité des résultats de mesure.
    EN SAVOIR PLUS
  • Construire un environnement de test de chambre d'essai sûr
    Sep 16, 2025
    La clé pour créer un environnement de test sûr pour le laboratoire chambre d'essai à haute et basse température Il s’agit de garantir la sécurité des personnes, la sécurité des équipements, la sécurité des pièces d’essai et l’exactitude des données.1. Considérations relatives à la sécurité personnelleAvant d'ouvrir la porte de la chambre haute température pour prélever l'échantillon, il est nécessaire de porter un équipement de protection résistant aux hautes et basses températures. Lors d'opérations susceptibles de provoquer des éclaboussures ou des fuites de gaz extrêmement chauds ou froids, il est recommandé de porter un masque ou des lunettes de protection.La chambre d'essai doit être installée dans un laboratoire bien ventilé et éviter de travailler dans un espace confiné. Les essais à haute température peuvent libérer des substances volatiles de la pièce d'essai. Une bonne ventilation peut empêcher l'accumulation de gaz nocifs.Assurez-vous que les spécifications du cordon d'alimentation sont conformes aux exigences de l'équipement et que le fil de terre est correctement connecté. Surtout, il est strictement interdit de toucher les fiches d'alimentation, les interrupteurs et les échantillons avec les mains mouillées afin d'éviter tout risque d'électrocution. 2. Installer correctement l'équipementLa distance de sécurité minimale spécifiée par le fabricant (généralement au moins 50 à 100 centimètres) doit être respectée à l'arrière, sur le dessus et sur les côtés de l'appareil afin d'assurer le bon fonctionnement du condenseur, du compresseur et des autres systèmes de dissipation thermique. Une mauvaise ventilation peut entraîner une surchauffe de l'appareil, une baisse de ses performances, voire un incendie.Il est recommandé de prévoir une ligne électrique dédiée à la chambre d'essai afin d'éviter de partager le même circuit avec d'autres équipements de forte puissance (tels que des climatiseurs et de gros instruments), ce qui peut provoquer des fluctuations de tension ou des déclenchements.Il est recommandé de maintenir une température ambiante de fonctionnement comprise entre 5 °C et 30 °C. Des températures ambiantes excessivement élevées augmenteront considérablement la charge du compresseur, entraînant une baisse de l'efficacité de la réfrigération et des dysfonctionnements. Veuillez noter que l'équipement ne doit pas être installé en plein soleil, à proximité de sources de chaleur ou dans des endroits soumis à de fortes vibrations. 3. Assurer la validité et la répétabilité des testsLes échantillons doivent être placés au centre de la chambre de travail, à l'intérieur de la boîte. Un espace suffisant doit être prévu entre les échantillons et entre eux et la paroi de la boîte (un espace généralement supérieur à 50 mm est recommandé) pour assurer une circulation d'air fluide et une température uniforme et stable.Après avoir effectué des tests à haute température et à haute humidité (par exemple dans une chambre à température et humidité constantes), si des tests à basse température sont nécessaires, des opérations de déshumidification doivent être effectuées pour éviter la formation excessive de glace à l'intérieur de la chambre, ce qui pourrait affecter les performances de l'équipement.Il est strictement interdit de tester des substances inflammables, explosives, hautement corrosives et hautement volatiles, à l'exception des enceintes antidéflagrantes spécialement conçues à cet effet. Il est strictement interdit de placer des marchandises dangereuses telles que l'alcool et l'essence dans des enceintes ordinaires à haute et basse température. 4. Spécifications de fonctionnement de sécurité et procédures d'urgenceAvant utilisation, vérifiez que la porte du boîtier est bien fermée et que le verrouillage fonctionne correctement. Vérifiez que le boîtier est propre et exempt de tout corps étranger. Vérifiez que la courbe de température réglée (programme) est correcte.Pendant la période de test, il est nécessaire de vérifier régulièrement si l'état de fonctionnement de l'équipement est normal et s'il y a des bruits ou des alarmes anormaux.Normes de manipulation et de placement des échantillons : Porter des gants adaptés aux températures élevées et basses. Après avoir ouvert la porte, se tourner légèrement sur le côté pour éviter que la vague de chaleur ne frappe le visage. Retirer rapidement et soigneusement l'échantillon et le placer dans un endroit sûr.Intervention d'urgence : Familiarisez-vous avec l'emplacement du bouton d'arrêt d'urgence de l'équipement et avec la procédure de coupure rapide de l'alimentation électrique principale en cas d'urgence. Des extincteurs à dioxyde de carbone (adaptés aux incendies électriques) doivent être installés à proximité, plutôt que des extincteurs à eau ou à mousse.
    EN SAVOIR PLUS
  • Guide de test basse pression pour chambre d'essai à trois combinaisons en laboratoire
    Sep 13, 2025
    Le système central du chambre d'essai à trois combinaisons Il se compose principalement d'une chambre d'essai sous pression, d'un système de vide, d'un système spécial de contrôle de la température et de l'humidité, et d'un contrôleur collaboratif de haute précision. Il s'agit essentiellement d'un ensemble complexe d'équipements intégrant une chambre de température et d'humidité, une table vibrante et un système de vide (hautement simulé). La réalisation d'essais basse pression est un processus de contrôle collaboratif précis. Prenons l'exemple de l'essai basse température-basse pression : 1. Étape de préparation : Installez fermement l'échantillon sur la table vibrante à l'intérieur de la boîte (si aucune vibration n'est requise, installez-le sur le support d'échantillons), fermez et verrouillez la porte de la boîte pour garantir l'efficacité de la bande d'étanchéité haute résistance. Définissez le programme d'essai complet sur l'interface de commande, y compris : les courbes de pression, de température, d'humidité et de vibration.2. Mise sous vide et refroidissement : Le système de contrôle active la pompe à vide et ouvre la vanne de vide pour extraire l'air contenu dans la boîte. Parallèlement, le système de réfrigération se met en marche, envoyant de l'air froid dans la boîte, ce qui entraîne une baisse de température. Le système de contrôle coordonne dynamiquement la vitesse de pompage de la pompe à vide et la puissance du système de réfrigération. En effet, lorsque l'air se raréfie, l'efficacité de la conduction thermique diminue considérablement et le refroidissement devient plus difficile. Le système peut ne pas refroidir complètement tant que la pression d'air n'atteint pas un certain niveau.3. Phase de maintenance basse pression/basse température : lorsque la pression et la température atteignent les valeurs de consigne, le système passe en mode maintenance. En cas de fuite minime dans un boîtier, le capteur de pression surveille la pression d'air en temps réel. Lorsque la pression d'air dépasse la valeur de consigne, la pompe à vide démarre automatiquement un léger pompage, maintenant la pression dans une plage très précise.4. L'humidification est l'étape la plus complexe. S'il est nécessaire de simuler une humidité élevée dans un environnement à haute altitude et à basse pression, le système de contrôle active le générateur de vapeur externe, puis injecte lentement la vapeur générée dans le caisson basse pression via une vanne de pressurisation et de dosage spéciale. Le capteur d'humidité assure le contrôle en retour.5. Une fois la période d'essai terminée, le système entre en phase de récupération. Le contrôleur ouvre lentement la soupape de surpression ou la vanne d'injection d'air pour permettre à l'air sec filtré d'entrer progressivement dans la boîte, permettant ainsi à la pression d'air de revenir progressivement à la normale. Lorsque la pression d'air et la température se stabilisent à température ambiante et à pression normale, le contrôleur envoie un signal indiquant la fin de l'essai. L'opérateur peut alors ouvrir la porte de la boîte et prélever l'échantillon pour des tests et une évaluation ultérieurs des performances. L'essai basse pression de la chambre d'essai à trois combinaisons est un processus extrêmement complexe, qui repose sur la coordination précise de sa chambre résistante à la pression, d'un puissant système de vide et d'un système de contrôle de la température et de l'humidité spécialement conçu pour les environnements basse pression. Il permet de simuler fidèlement les épreuves difficiles que subissent simultanément les produits en haute altitude et dans d'autres environnements, notamment le froid intense, le manque d'oxygène (faible pression atmosphérique) et l'humidité. C'est un appareil d'essai essentiel dans des domaines tels que l'aérospatiale, l'industrie militaire et l'électronique automobile.
    EN SAVOIR PLUS
  • Comment choisir la méthode de refroidissement appropriée pour les chambres d'essai ?
    Sep 09, 2025
    Le refroidissement par air et le refroidissement par eau sont deux méthodes de dissipation thermique courantes dans les équipements de réfrigération. Leur principale différence réside dans les différents fluides utilisés pour évacuer la chaleur générée par le système vers l'extérieur : le refroidissement par air utilise de l'air, tandis que le refroidissement par eau utilise de l'eau. Cette différence fondamentale a donné lieu à de nombreuses distinctions en termes d'installation, d'utilisation, de coût et de scénarios d'application. 1. Système refroidi par airLe principe de fonctionnement d'un système de refroidissement par air consiste à forcer le flux d'air à travers un ventilateur, qui le souffle sur son composant principal de dissipation thermique, le condenseur à ailettes, évacuant ainsi la chaleur du condenseur et la dissipant dans l'air ambiant. Son installation est très simple et flexible. L'équipement fonctionne simplement par raccordement électrique et ne nécessite aucune installation supplémentaire, ce qui réduit les besoins en rénovation de site. La performance de refroidissement est fortement influencée par la température ambiante. En été chaud ou dans des environnements à haute température et mal ventilés, la faible différence de température entre l'air et le condenseur entraîne une baisse significative de l'efficacité de dissipation thermique, ce qui entraîne une diminution de la capacité de refroidissement de l'équipement et une augmentation de la consommation d'énergie opérationnelle. De plus, le ventilateur est très bruyant pendant le fonctionnement. L'investissement initial est généralement faible et l'entretien quotidien est relativement simple. La principale tâche consiste à dépoussiérer régulièrement les ailettes du condenseur pour assurer une ventilation optimale. Le principal coût d'exploitation est la consommation d'électricité. Les systèmes refroidis par air conviennent parfaitement aux équipements de petite et moyenne taille, aux zones avec une électricité abondante mais des ressources en eau rares ou un accès à l'eau difficile, aux laboratoires avec des températures environnementales contrôlables, ainsi qu'aux projets avec des budgets limités ou ceux qui préfèrent un processus d'installation simple et rapide. 2. Système refroidi par eauLe principe de fonctionnement d'un système de refroidissement par eau consiste à utiliser de l'eau circulant dans un condenseur dédié pour absorber et évacuer la chaleur du système. L'eau chauffée est généralement acheminée vers la tour de refroidissement extérieure pour y être refroidie, puis recyclée. Son installation est complexe et nécessite un ensemble complet de systèmes d'eau externes, comprenant des tours de refroidissement, des pompes à eau, des réseaux de canalisations et des dispositifs de traitement de l'eau. Cela impose non seulement un emplacement précis pour l'installation de l'équipement, mais impose également des exigences élevées en matière d'aménagement du site et d'infrastructure. La dissipation thermique du système est très stable et n'est pratiquement pas affectée par les variations de température extérieure. Par ailleurs, le bruit de fonctionnement à proximité du corps de l'équipement est relativement faible. Son investissement initial est élevé. Outre la consommation électrique, d'autres coûts s'ajoutent, tels que la consommation continue d'eau lors du fonctionnement quotidien. La maintenance est également plus professionnelle et complexe, et il est nécessaire de prévenir l'entartrage, la corrosion et la prolifération microbienne. Les systèmes refroidis par eau conviennent principalement aux équipements industriels de grande taille et de grande puissance, aux ateliers avec des températures ambiantes élevées ou de mauvaises conditions de ventilation, ainsi qu'aux situations où une stabilité de température et une efficacité de réfrigération extrêmement élevées sont requises. Choisir entre le refroidissement par air et le refroidissement par eau ne consiste pas à juger leur supériorité ou infériorité absolue, mais à trouver la solution la mieux adaptée à ses conditions spécifiques. Le choix doit se baser sur les considérations suivantes : tout d'abord, les équipements de grande puissance privilégient généralement le refroidissement par eau pour des performances stables. Il convient également d'évaluer le climat géographique du laboratoire (chaleur ou non), les conditions d'alimentation en eau, l'espace d'installation et les conditions de ventilation. Ensuite, si l'investissement initial est relativement faible, le refroidissement par air est un choix judicieux. Si l'efficacité énergétique et la stabilité opérationnelles à long terme sont primordiales, et que le coût de construction initial relativement élevé ne pose pas de problème, le refroidissement par eau présente davantage d'avantages. Enfin, il est important de vérifier si l'on possède les compétences professionnelles nécessaires à la maintenance régulière de systèmes d'eau complexes.
    EN SAVOIR PLUS
1 2 3 4 5 6
Un total de 6pages

laisser un message

laisser un message
Si vous êtes intéressé par nos produits et souhaitez en savoir plus, veuillez laisser un message ici, nous vous répondrons dès que possible.
soumettre

Maison

Des produits

WhatsApp

Contactez-nous